Legrand Home + Control smart home integration, free and open source

Legrand Home + Control integration for Gladys Assistant

Céliane, dooxie with Netatmo and Bubendorff iDiamant: lights, outlets, shutters, meters.

Control the Céliane with Netatmo and dooxie with Netatmo modules of your Legrand Home + Control gateway from Gladys: lights and dimmers, power outlets, contactors, roller shutters and energy meters. The integration talks to the Netatmo cloud (the service behind the Home + Control app) with the official Netatmo Connect API, on your behalf. Unofficial integration, not affiliated with Legrand or Netatmo.

Development version (0.1). Developed against the Netatmo documentation and recorded answers, not yet tested on a real installation. Your feedback is welcome on the GitHub repository.

What you get​

ModuleIn Gladys
Power outlet, mobile socket, cable outlet (NLP, NLPM, NLC)a switch: on/off and power (W)
Teleruptor, contactor, dry contact (NLPT, NLPO, NLPD)a switch (a light when it drives a light)
Light switch, micromodule, double switch (NLL, NLM, NLIS)a light: on/off and power (one per gang)
Dimmer (NLF, NLFN, NLFE)a light: on/off, brightness and power
Roller shutter switch (NLV, NLLV), Zigbee covering (Z3V)a shutter: open, close, stop (and position)
DIN energy meter, load shedder, three-phase meter (NLPC, NLPS, NLY)power drawn (per phase for NLY)
Remote control (NLT, NLD)battery level
Bubendorff iDiamant shutter (NBR, NBO, NBS)a shutter: open, close, stop (and position)

The position of a shutter is offered for the modules that accept any position (NLLV, and the shutters that report a step under 100); the others open, close and stop. Each device shows on its badge whether the module answers.

Bubendorff iDiamant with Netatmo shutters​

The Bubendorff shutters behind an iDiamant gateway (NBG) go through the same Netatmo Connect API: they show up in Discovery as shutters (never as switches), with open, close and stop, and a position only when the module reports one (most iDiamant shutters only open, close and stop). The favourite position of the Bubendorff remote is not offered yet.

Never tested with real Bubendorff shutters: developed from the answers recorded by pyatmo. Your feedback is welcome.

The Connect button now also asks for the Bubendorff rights (read_bubendorff, write_bubendorff). If you connected before this version, nothing changes for your Legrand modules; when Bubendorff shutters are found without the write_bubendorff right, the status asks you to click Connect again to add Bubendorff. If your Netatmo app does not offer these rights, the integration falls back to the Home + Control rights alone: at once when Netatmo refuses them while linking, and otherwise when you click Connect again after a Netatmo authorization page that did not bring you back to Gladys (that one click asks for the Home + Control rights only).

A shutter command is never sent late: one at a time per shutter (a stop never waits), refused if Netatmo could not take it within four seconds, and reported as sent, without confirmation when it left without an answer, the state being read again a few seconds later.

Not yet: cable outlets in pilot-wire mode (radiators: their power only), ventilation (NLLF), garage door (NLJ), the ecometer lines (NLE), the button presses of the remotes, energy history. They are planned.

Installation​

You need a Netatmo app of your own (free, five minutes): it gives the integration the right to use the API with your account.

  1. Go to dev.netatmo.com and sign in with the account of the Home + Control (or Bubendorff iDiamant) app.
  2. Create an app: any name and description (e.g. "Gladys"), your name and email as data protection contact.
  3. In the Gladys configuration of the integration, copy the redirect URI Gladys shows for the Connect button, and paste it in the Redirect URI field of the Netatmo app. Save the app.
  4. Copy the client ID and the client secret of the app into the Gladys configuration, and save.
  5. Click Connect: Netatmo asks you to sign in and to accept the Home + Control rights (read_magellan, write_magellan) and, for the Bubendorff shutters, read_bubendorff and write_bubendorff. You come back to Gladys, connected.
  6. Open the Discovery tab: your modules are there, add the ones you want.

Test the connection shows how many homes and devices were found.

Options​

OptionDefaultPurpose
Refresh interval60 show often the states are read (one minute minimum, max 1 hour)

A command is sent at once and the state is read again a few seconds later. Netatmo limits the requests (500 per hour per user): the integration spaces them, sends the commands of a same moment together and pauses when Netatmo asks it to. With several homes or many commands, a longer interval is safer.

Troubleshooting​

  • "Netatmo refused the authorization": the authorization expired or was revoked (from the Netatmo account), or the client secret is wrong. Check the client ID and the client secret, save, then click Connect again.
  • The Connect page shows an error: the redirect URI of the Netatmo app is not exactly the one Gladys shows (copy it again, without a space).
  • "Read only": the Home + Control rights were not all accepted: click Connect again and accept them.
  • "click Connect again to add Bubendorff": your authorization predates the Bubendorff rights. Click Connect and accept them; the Legrand modules keep working meanwhile.
  • "usage limit reached": Netatmo asked to slow down; the integration retries by itself. Increase the refresh interval if it comes back.
  • A module is missing: the logs list the modules the integration cannot show yet; Test the connection counts them.
  • A device shows "unreachable": the module or the gateway does not answer Netatmo (power cut, Wi-Fi of the gateway).

Privacy​

The integration only talks to api.netatmo.com, with your own Netatmo app. The client secret and the tokens are stored by Gladys and never appear in the logs. Nothing goes through Gladys Plus.

Configuration settings​

These are the settings Legrand Home + Control asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Your Legrand Home + Control installationsectionNoControl the Céliane with Netatmo and dooxie with Netatmo modules of your Home + Control gateway through the Netatmo cloud: lights and dimmers, outlets, contactors, roller shutters and energy meters; and the Bubendorff iDiamant with Netatmo shutters (never tested with real Bubendorff shutters). 1. Sign in on dev.netatmo.com with your Home + Control or iDiamant account and create an app. 2. In its Redirect URI field, paste the redirect URI Gladys shows for the Connect button below. 3. Copy the client ID and the client secret of the app here and save. 4. Click Connect and accept the Home + Control and Bubendorff rights. Unofficial integration, not affiliated with Legrand, Bubendorff or Netatmo.
Client IDstringYesThe client ID of the app you created on dev.netatmo.com.
Client secretsecretYesThe client secret of the same app. Stored in Gladys, never shown again.
Netatmo accountoauth2NoSave the client ID and the client secret first, then connect: Netatmo asks you to sign in and to accept the Home + Control rights (read_magellan, write_magellan) and the Bubendorff ones (read_bubendorff, write_bubendorff). Linked before? Your Legrand modules keep working; connect again only to add Bubendorff.
Refresh interval (s)numberNoHow often the states are read from Netatmo, in seconds (one minute minimum, within the Netatmo usage limits). A command is confirmed a few seconds after it is sent.

How to install Legrand Home + Control in Gladys​

  1. In Gladys, open Integrations: Legrand Home + Control appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/lm1lc3n7/gladys-legrand-home-control:0.1.3), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/LM1LC3N7/gladys-legrand-home-control.

Legrand Home + Control requires Gladys >=5.1.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

Legrand Home + Control is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by LM1LC3N7, not by the Gladys core team.

Subscribe to the Gladys Assistant newsletter

A few emails per month about new releases and project news. Sent by Pierre-Gilles Leymarie, founder of the project. Unsubscribe anytime 🙂